TM 5-6115-590-12
clean rag moistened with an approved cleaning solvent.
2. Visually inspect terminal board for
corrosion, cracks, damaged threads or other evidence of
damage.
(c) Installation. Install the terminal board in
reverse order of removal procedures.
(4) Wiring Harness (To Connectors J14, J53, J54,
J55, J56, J70, J76).
(a) Removal. Tag and disconnect wires as
necessary. Remove four nuts, eight washers, and four
screws to remove each wiring harness.
(b) Cleaning, Inspection and Repair.
1. Clean connectors on harnesses
using filtered compressed air. Wipe wires off using rag
moistened with dry cleaning solvent.
2. Visually inspect connectors for
cracks, corrosion, burns, or other damage. Inspect
wires for breakage of insulation.
3. Replace harnesses damaged
beyond repair.
(c) Installation. Install by reversing removal
procedures.
(5)
Bracket
and
Air
Conditioning
Panel
Assemblies (fig. 4-22).
(a) Removal.
1. Prior to removal of either the
bracket
assembly
or
the
air
conditioning
panel
assembly, visually inspect for dents, bends, or other
damage. If inspection reveals damage which would
necessitate the replacement of either panel or bracket,
all components which are attached to the part must be
removed. See the applicable paragraphs for removal of
each component.
2. Remove bracket assembly from
the air conditioning panel by removing four screws and
eight washers.
(b) Cleaning, Inspection and Repair.
1. Clean the bracket and panel with
dry cleaning solvent.
2. Inspect the bracket and panel for
dents, bending, corrosion, or other damage.
3. Replace parts damaged beyond
simple shop repair.
(c) Installation. Install by reversing removal
procedures.
4-36. Temperature Control Panel Assembly
Maintenance procedures for components mounted on
the temperature control panel (fig. 4-23) consists of
cleaning, removal, and replacement of damaged
components.
WARNING
The power plant shall not be operating
when
maintenance
on
electrical
components is being performed, and
the
power
plant
shall
not
be
connected to another power plant that
is operating.
NOTE
Access to the temperature control
panel is obtained by removing four
bolts and four washers from the
perimeter of panel. Carefully work
panel out far enough to gain access to
component parts. If entire panel Is to
be
removed,
disconnect
electrical
connector (P94) and remove panel.
a. Panel Illumination Lamp Assembly (DS 22).
(1) Removal. Tag and disconnect electrical
connections to lamp assembly: Remove nut and washer
from lamp assembly. Remove lamp assembly from
panel.
(2) Cleaning and Inspection.
(a) Clean lamp assembly with filtered
compressed air and an electrician's brush or wipe with a
clean rag moistened with an approved cleaning solvent.
(b) Visually inspect lamp assembly
for corrosion, cracks, damaged threads or other
evidence of damage.
(3) Installation Install lamp assembly in
reverse order of removal procedure
b. Cooled Air System Indicating Lamps (DS20
and DS21).
(1) Removal Tag and disconnect electrical
connections to lamp assembly. Remove nut and washer
from lamp assembly. Remove lamp assembly from
panel.
(2) Cleaning and Inspection.
(a) Clean lamp assembly with filtered
compressed air and electrician's brush or wipe with a
clean rag moistened with an approved cleaning solvent.
(b) Visually inspect lamp assembly for
corrosion, cracks, damaged threads or other evidence of
damage.
(3) Installation. Install in reverse order of
removal procedure.
4-37. Auxiliary Power Tray Assembly
Maintenance of the auxiliary power tray assembly (fig.
4-24) consists of cleaning and removal and replacement
of damaged or malfunctioning components. The tray
assembly is located behind the batteries in the battery
compartment. Access to the tray assembly is obtained
by opening the battery compartment access door and
removing the metal shield covering the tray assembly.
WARNING
Electrical power shall be shut off
before performing maintenance on the
auxiliary power tray assembly.
a. Thermal Relay.
(1) Removal.
(a) Tag and disconnect electrical
connections to thermal relay (4) Remove bus bars (5)
and (6).
Change 6 4-57