FAULT CODE DE, 400 HZ RESOLVER REFERENCE EXPANDED INSTRUCTIONS
Figure 124. Fault Code E1, T4.5 Sensor (sheet 1 of 2)
TM-1-2840-252-23-3 Engine Gas Turbine Model T55-L-714 Manual
Page Navigation
700
701
702
703
704
705
706
707
708
709
710
TM
1-2840-252-23-3
G-37
FAULT
CODE
DE,
400
HZ
RESOLVER
REFERENCE
EXPANDED
INSTRUCTIONS
(CONTINUED)
RESISTANCE
-CHECK
SUMMARY
Resistance
(Ω)
Connector
Component
No.
Contacts
Limits
Nominal*
ECL
Quadrant
PL3
h&i
35 - 42
-
EE & DD
90-
102
-
ECL
Quadrant
1&2
35 - 40
-
3 &4
90 -
100
-
RTL
Sensor
PL3
z & AA
110
-
140
-
q&p
210
-260
-
LVDT
1&2
110
-
140
-
3&4
210
-
260
-
3&5
<
230
-
4&5
<
230
-
*At
25
C
-