G-21 FAULT CODE F7, BLEED VALVE SOLENOID EXPANDED INSTRUCTIONS
Step 2.
Check harness connector PL1 (igure 201) at DECU, and P4 at HMA for tight connections.
Step 3.
Disconnect connectors PL1 and P4 to check pins and sockets.
Step 5.
With PL1 disconnected, check resistance of HMA (bleed valve solenoid) at harness PL1
Step 6.
pins E and F. Limit is 27- 62Ω.
Step 7.
Before tightening harness connectors PL1 and P4, be sure that keyways in harness conne
c-
tors are aligned with keyways in component connectors.
Step 12. Refer to manufacturer's procedure for diagnosing and replacing harness.
Step 14
Refer to manufacturer's procedure for diagnosing and replacing harness.
RESISTANCE-CHECK SUMMARY
Resistance (Ω)
Connector
Component
No.
Contacts
Limits
Nominal *
HMA - Bleed Valve Solenoid
PL1
r&s
27 - 62
42
*At 25
C
J4
E&F
27 - 62
42