TM 1-2840-252-23-3
7-23
CLEAN REVERSIONARY ELECTRICAL HAIRNESS ASSEMBLY
7-23
INITIAL SETUP
Equipment Condition:
Applicable Configurations:
Off Engine Task
All
Reversionary Electrical Harness Assembly Re-
Tools:
moved (Task 7-22)
General Safety Instructions:
WARNING
Goggles
Denatured alcohol (E17) is flammable
Dry, Compressed Air Source
and toxic. It can irritate skin and cause
Materials:
burns. Use only in well-ventilated area,
Gloves (E24)
away from heat and open flame. In case
Lint-Free Cloth (E30)
of contact, immediately flush skin or
Denatured Alcohol (E17)
eyes with water for at least 15 minutes.
Personnel Required:
Get medical attention for eyes.
1. Wear gloves (E24). Clean reversionary electrical
harness assembly (1). Use lint-free cloth dampened with
Denatured alcohol (E17). Wipe dry using clean, dry, lint-free
cloth (E30).
2. Clean seven electrical connectors (2).
Use
denatured alcohol (El 7) and brush.
WARNING
When using compressed air for cleaning, use
approved protective equipment for eyes and
face.
Do not use more than 30 psig air
pressure. Do not direct air toward yourself or
another person. Failure to comply could result
in injury to eyes or skin. In case of injury, get
medical attention.
3. Wear goggles. Blow dry electrical connectors (2).
Use clean, dry, compressed air.
FOLLOW-ON MAINTENANCE:
Inspect Reversionary Electrical Harness Assembly
(Task 7-24).
END OF TASK
7-115