TEST PRIMARY ELECTRICAL HARNESS ASSEMBLY (Continued)
7-20
gc.
gd.
Touch red probe (2) to electrical connector (30), sleeve X (65).
ge.
Touch black probe (5) to electrical connector (60), pin C (66).
gf.
Meter shall indicate zero ohms.
gg.
gh.
Touch black probe (5) to all other pins on electrical connector (60).
gi.
Meter shall indicate 1000 ohms minimum.
FOLLOW-ON MAINTENANCE:
None
END OF TASK