TM 1-2840-252-23-3
7-5
INSTALL IGNITION COIL AND CABLE ASSEMBLY (Continued)
7-5
23. Install spark Igniter (40) on ignition lead (41).
CAUTION
To prevent shorting of ignition lead, do
not allow anti-seize compound to touch
24. Coat threads of ignition lead (41) with anti-seize
compound (E6).
25. Install ignition lead (41). Torque to 135 inch-
pounds. Use crowfoot attachment. Lockwire ignition
lead (41). Use lockwire (E33).
26. Install two clamps (42) and screw (43).
Lockwire
screw (43). Use lockwire (E33).
GO TO NEXT PAGE
7-47