CAUTION
When installing fireshield assembly, be
careful not to get five thermocouple
harness assembly leads caught between
fireshield and fourth turbine nozzle.
Failure to comply may cause damage to
harness assembly leads.
22. Align fireshield assembly (31) near 23 supports (9) with
thermocouple jumper lead mounting hole (32) at 5-
o'clock position.
23. Route five thermocouple harness assembly leads (33)
through five cutouts (34) in fireshield assembly (31).