TM 1-2840-252-23-2
4-61
REPAIR SECOND TURBINE NOZZLE, SPACER, CASE, AND BUMPER
4-61
(AVIM) (Continued)
Install mechanical puller (32), art of skimming
37.
p
maintenance kit (T44) on adapter (5) Tighten puller
(32) until it bottoms on adapter (5).
38.
Loosen three bolts (6) until they are free of baffle
retainer (4).
In following step, support adapter while it is
being removed. Failure to comply will cause
damage to second turbine nozzle.
Turn handle (33) clockwise until adapter (5) is
39.
removed.
GO TO NEXT PAGE
4-352