TM 1-2840-252-23-2
3-17 INSPECT COMBUSTION CHAMBER LINER (AVIM) (Continued)
3-17
Inspect joints (13). There shall be no more than
e.
five broken or cracked spotwelds (14) in a row
(15).
Inspect four inner liners (16, 17, 18, and 19) as
2.
follows
a.
There shall be no cracks (20) longer than 1 inch.
There shall be no cracks less than 5 Inches apart
on liners (16 and 17) or less than 2 inches apart
on liner (18) In addition, there shall be one portion
with no more than two adjacent cracks (21) on
inner liners (16, 17, 18, and 19). These cracks
shall be no less than 1 inch apart.
GO TO NEXT PAGE
3-148