3-14 INSPECT COMBUSTION CHAMBER VANE ASSEMBLY (AVIM) (Continued)
3-14
b.
Inspect outer shroud (13) s follows:
a
(i)
There shall be no cracks (14 and 15) which do not
have minimum separation (16).
(a) Minimum separation (16) shall be equal to the
length (17) of shorter crack (14).
(2) Inspect brazement (18) between short vane (19)
and outer shroud (13). There shall be no cracks or
lack of braze (20) longer than 1/16 inch.