TM 1-2840-252-23-2
3-5
REMOVE COMBUSTION SECTION AND POWER TURBINE (AVIM) (Continued)
3-5
WARNING
move one lead at a time and discharge
receptacle that lead was removed from.
Failure to do so may result in serious
shock when you are removing second
lead In case of serious shock, get med-
ical attention.
NOTE
Steps 3 and 4 apply to both output recep-
tacles.
3. Remove lockwire and disconnect ignition coil
and cable assembly leads (7)
4. Discharge ignition exciter (8) y placing tip of
b
Insulated screwdriver (9) against pin (10) and
edge (11) of receptacle (12)
5. Place ignition coil and cable assembly leads (7) to
one side
GO TO NEXT PAGE
3-12