TM 1-2840-252-23-2
2-56
INSTALL T1 TEMPERATURE SENSOR (Continued)
2-56
Install T1 temperature sensor (1)nto inlet housing
1.
i
(2) and torque to 90 inch-pounds.
Lockwire T1 temperature sensor (1to nut (3) Use
)
2.
lockwire (E33).
NOTE
In following step, it may be necessary to remove
lockwire from electrical connector and reorient
connector for proper installation Be sure to lockwire
electrical connector if lockwire was removed.
Connect electrical connector (4to T1 temperature
)
3.
sensor (1).
INSPECT
FOLLOW-ON MAINTENANCE
None
END OF TASK
2-365/(2-366 blank)