CAUTION
4-15 REPLACE FUEL SOLENOID VALVE (CONT)
REMOVAL
To prevent clogging or contam-
ination, all exposed openings
in fuel, oil, air lines and
electrical connectors will be
capped immediately.
Be sure
caps and plugs are clean.
1.
2.
3.
4.
5.
6.
7.
8.
Remove fuel control upper cover
(Task 4-1).
Disconnect electrical connector (1)
from solenoid valve (11).
Place machinery towel (D20) under
solenoid valve (11).
Disconnect fuel control assembly to
fuel solenoid valve tube (2).
Disconnect fuel solenoid valve to
fuel manifold assembly tube (3) from
fuel solenoid valve (11).
Remove reducer (4) and union (5)
from solenoid valve (11). Remove
packings (6) from reducer and union
and discard.
Remove nuts (7), bolts (8), washers
(9). spacers (10) and packings with ,
retainer (10.1) securing solenoid
valve (11) to fuel control lower
cover.
Remove solenoid valve (11).
Clean solenoid valve using process
7, Chapter 8.