TM 55-2835-208-23
2-66 INSTALL MAX AND START FUEL SOLENOID VALVES (Continued)
2-66
5.
6.
7.
8.
9.
Install combined max and start fuel sole-
noid valves and doubler (12). Secure
with washers (11) and screws (10). Safe-
ty wire screws (10) with lockwire (E32).
Connect tube assembly (1). Torque B-
nuts (7) to 80 inch-pounds. Torque bolt
(16) to 45 inch-pound.
Install tube assemblies (3, 2) and torque
B-nuts (26) to 80 inch-pounds.
Install fuel inlet filter (Task 2-59).
Connect connector P305 (4) to J305 (6)
and connector P307 (5) to J307 (7).
Safety wire connectors with lockwire
(E32).
10. Install main fuel solenoid valve (Task
2-64).
11. Install fuel control cover (Task 2-46).
INSPECT
FOLLOW-ON MAINTENANCE:
Leak Check During Operation
END OF TASK
Change 4
2-127