4-79. WIRING HARNESSES. (cont)
h. Wiring Harness
W3 Insta llation.
(cont)
(11) Remove
tag
and
connect
wiring harness W3 electrical connectors
to low oil pressure switch, monopole
speed sensor,
EGT thermocouple, and
ignition coil.
(12) Pass remainder of w
harness W3 through bulkhead into
housing.
(13) Secure grommet plate
bulkhead with washers and screws.
iring
fuel
t o
See
(14) Remove t a gs
a nd
connect
wiring harness W3 electrical connectors
to transfer pump, solenoid valve, and
high pressure pump.
(15) Install
loop
clamps
with
screws, washers, and nuts.
(16) Close and securely latch
fuel housing access door.
(17) Install
engine
housing
access cover and secure with turnlock
fasteners.
(18) Stow power cable on cable
support.
(19) Connect battery cable plug
connector to battery.
figure 4-47.